    126kv intelligent combination electrical appliance

      yhk46 three remote cover type ftu

      overview

      ​ realize on-site clearing of faults, automatic isolation of faults, automatic transfer of power supply, and automatic restoration of power supply in non faulty sections; functions such as logic manual and automatic reset. realize on-site clearing of faults, automatic isolation of faults, automatic transfer of power supply, and automatic restoration of power supply in non faulty sections; functions such as logic manual and automatic reset.

      performance characteristics

      three remote functions protection function intelligent distributed logic function remote/local operation power function communication function wireless communication status indication data processing function fault detection

      product features

      three remote functions: telemetry (including direct flow), remote signaling, and remote control;

      protection functions: three-phase three-section overcurrent protection function, zero sequence protection function, reclosing and blocking reclosing function;

      intelligent distributed logic function: achieving local fault clearing, automatic fault isolation, automatic transfer of power supply, and automatic restoration of power supply in non faulty sections; logic manual, automatic reset and other functions;

      remote/local operation: the remote/local closing and opening operations are mutually locked, and the control outlet is controlled by the soft and hard pressing plates for on/off;

      power function: dual power switching, automatic seamless switching to backup power supply in case of ac power loss, and automatic management (battery activation, alarm, protection) function for backup power supply;

      communication function: multiple network and serial ports, supporting multiple communication protocols; wireless communication: capable of wireless communication through touch laptops;

      wireless communication: capable of wireless communication through touch laptops;

      status indication: there are obvious local status indication signals for operation, communication, line faults, etc;

      data processing function: arbitrary configuration and combination of data sent by the main station; distribution transformer load rate, three-phase imbalance, remote sensing exceeding limit, extreme value, qualification rate statistics, etc;

      fault detection: achieving on-site fault clearing, automatic fault isolation, automatic transfer of power supply, and automatic restoration of power supply in non fault sections; logic manual, automatic reset and other functions;

      technical parameter

      telemetry

      rated voltage

      ac220v/100v, accuracy 0.5%

      rated current

      5a/1a, accuracy 0.5%

      power (active, reactive, power factor)

      ≤ 1%

      dc voltage

      accuracy 0.2%

      remote signaling

      remote signaling power supply

      dc24v/dc48v adaptive

      soe resolution

      ≤ 2ms

      software anti shake time

      0-65535ms can be set

      single/dual point remote signaling optional

       

      remote control

      output method

      empty contact output, pulse duration 1-65535ms can be set

      contact rating

      ac 250v/5a, dc 80v/2a, or dc 110/0.5a pure resistive load

      contact life

      on/off 105 times

      telemetry

      ua, ub, uc, u0 (or uab, ubc), ia, ib, ic, i0 (or synthetic), 1 dc quantity